Generator sound insulation

We reduce the 95-110 dBA noise from diesel and gas generators by 45-55 dB using multi-layer enclosures, splitter silencers, acoustic doors and vibration-damping bases.

Summary

Generator sound insulation is a multi-layer engineering treatment that isolates the continuous high-decibel (95-110 dBA) noise of diesel and gas generators from interior spaces and the surroundings. Double-leaf walls + splitter silencer + certified acoustic door + vibration-damping base together deliver 45-55 dB reduction; in our practice we have certified 48 dB on a single project.

What is generator sound insulation?

Generator-room sound insulation is a comprehensive acoustic-enclosure design that brings the engine and exhaust noise plus vibration of the generator under control and prevents leakage into adjacent rooms and the environment. Unlike residential insulation, continuous high dB, temperature, vibration and airflow conditions are addressed simultaneously.

When is it needed?

  • Generator-room design in a new building
  • Environmental noise compliance (45 dBA night, 55 dBA day)
  • Office / residential complaint next door
  • Identified administrative-fine risk
  • Estate / mall management acoustic requirements

How is the multi-layer enclosure built?

  1. Existing concrete wall + vibroacoustic hangers
  2. Steel frame with 80 mm high-density rock-wool fill
  3. Two layers of acoustic plasterboard at differing thickness
  4. Elastomeric membrane (Tecsound) between the boards
  5. Sound-absorbing acoustic panel on the inside (echo control)
  6. Acoustic door (Rw 38-44 dB certified)
  7. Splitter silencers at air inlet and outlet
  8. Reactive silencer on the exhaust line (high-temperature)
  9. Elastomer vibration-damping base beneath the generator

Air inlet/outlet — the critical point

An insulated wall delivering 60 dB performance drops to 25 dB at a bare 30 cm ventilation opening. Splitter silencers at air inlets/outlets are therefore mandatory; a correctly designed silencer adds 25-40 dB without obstructing flow.

Vibration — never overlook it

Even when airborne sound is controlled, generator vibration travels through the structure and is felt as a "rumble" upstairs. Structural transmission is cut not by acoustic panels but by correctly chosen elastomer vibration isolators. A wrong isolator can resonate at the operating frequency and amplify vibration.

Target performance

  • 45-50 dB net reduction: our site standard
  • 55+ dB: high-comfort projects
  • Environmental dB limit: 45 dBA night, 55 dBA day
  • Indoor dB: 30-40 dBA in adjacent rooms

Field story

For a 1250 kVA diesel generator at a logistics facility in Istanbul, we applied multi-layer wall + 80 mm rock wool + double plasterboard + intermediate membrane + interior polyester panel + 2 m splitter silencer + reactive exhaust silencer + Rw 44 dB acoustic door. The final measurement documented 48 dB net reduction.

Lead time and cost

A typical generator-room application runs 2-4 weeks. Investment depends on enclosure size, silencer dimensions and target dB. Compared with the environmental-fine risk, the investment pays back quickly.

Certificates

All materials carry EN 13501-1 A2-s1, d0; BS 476 Class 0; UNI 9175 Class 1IM. Silencers comply with EN ISO 7235.

Features

On-site acoustic measurement and noise source analysis

Detailed engineering with professional simulation software

Certified material selection (BS476 Class 0, UNI 9175)

Meticulous installation and execution with our experienced team

Final measurement and performance warranty report

Process

01

Survey & Measurement

On-site survey and acoustic measurement.

02

Simulation & Design

Simulation with acoustic software, detailed quote.

03

Installation

Turnkey installation with certified materials.

04

Verification & Report

Final measurement, performance report, warranty.

Technical Specifications

Application Standard BS476 Class 0, UNI 9175 M1, Firex
Typical Noise Reduction 25-45 dB (project-dependent)
Installation Time Confirmed after survey (1-15 days)
Warranty Measured result + 2-year workmanship warranty

Frequently Asked Questions

Generator soundproofing — which materials do you use?
Depending on project requirements, we use acoustic foam, barrier-backed foam, lead/EPDM barrier, elastomeric rubber, rock wool and double-layer plasterboard systems. All our materials carry international fire-resistance certifications.
How much noise reduction do I get after the application?
It varies according to the existing structure, the adjacent noise level and the target use. Typical residential applications achieve 25-40 dB and industrial projects 35-55 dB. The exact value is confirmed by acoustic measurement.
Do I need to move my existing furniture?
It is enough to clear sufficient space so we can work in the application area. Our installation team takes protective measures for furniture; for small applications minimal rearrangement is sufficient.
How can I request a quote?
You can reach us by phone (+90 530 044 09 90), WhatsApp or our contact form. After a brief conversation we schedule an on-site survey.

Get an expert opinion for your project

Our team is ready for acoustic measurement, detailed engineering and turnkey delivery.

Get a Quote Call Now WhatsApp